GLASDAN 30 P PLAST
APP plastomeric 3 kg/m² underlay. Torch applied.
Product variations:

LBM-30-FV type bituminous waterproofing sheet for unprotected surfaces (APP -10 ºC).
Composed of a glass fibre felt reinforcement, coated on both sides with a bitumen mastic modified with plastomers (foldability -10ºC), using a plastic film on both sides as an anti-adherent material. The bottom side is embossed.
Advantages & Benefits
- Increases performance on the site.
- A better performing membrane than an oxyasphalt sheet of similar characteristics. It also performs better than a -5°C flexible modified bitumen sheet.
- Little thermal variation.
- Better melting.
- High dimensional stability.
- As it's made from polymer-modified bitumen mastic and in comparrison to oxyasphalt sheets, the membrane provides, high performance at high and low temperatures, plasticity and resistance to ageing, which leads to a longer durability of the sheet and the safety of the waterproofing membrane.
- Limits deformations.
- Limits stresses in the waterproofing membrane.
- Allows for adaptation to any type of geometry.
Instruction for Use
Preparation of the substrate:
The surface of the base substrate shall be resistant, uniform, smooth, clean, dry and free of foreign bodies. In the case of thermal insulation, the boards shall be laid in a joint pattern and without gaps of more than 0.5 cm between boards.
The surface of the base substrate shall be resistant, uniform, smooth, clean, dry and free of foreign bodies. In the case of thermal insulation, the boards shall be laid in a joint pattern and without gaps of more than 0.5 cm between boards.
- Lower reinforcement in improved single-layer waterproofing membranes for waterproofing roofs with adhered heavy protection (PA-6 and PA-9 membrane according to the UNE 104-402/96 standard) and adhered self-protected (GA-1 membrane according to the UNE 104-402/96 standard). The adhesion of the membrane to the substrate is carried out with a blowtorch. In the case of mortar or concrete substrates, a bituminous primer (Curidán, Impridán 100, Maxdán or Maxdán Caucho) must be applied beforehand. The overlaps must be welded, and shall be 8 cm in both longitudinal and transverse directions.
- Lower reinforcement in improved single-layer waterproofing membranes for waterproofing roofs with heavy non-adhered or floating protection (PN-1 and PN-8 membrane according to the UNE 104-402/96 standard). The adhesion of the membrane to the substrate is done with a blowtorch. In the case of mortar or concrete substrates, a bituminous primer (Curidán, Impridán 100, Maxdán or Maxdán Caucho) must be applied beforehand. . The overlaps must be welded, and shall be 8 cm in both longitudinal and transversal directions.
Indications and Important Recommendations
- In case of new construction and renovation, possible chemical incompatibilities with other sheets shall be taken into account.
- In case of refurbishment, chemical incompatibilities with old waterproofing systems consisting of PVC membranes, modified tar-based mastics or any other, shall be taken into account, and it may be necessary to remove them completely or to use suitable separating layers.
- If it is necessary to adhere to metallic or slightly porous elements, a bituminous primer (IMPRIDAN 100) shall be applied to the entire surface to be welded beforehand.
- This product may form part of a waterproofing system, so all the documents referred to in the Danosa Solutions Manual must be taken into account, as well as all the regulations and legislation that must be complied with in this respect.
- Danosa waterproofing fims should be installed preferably within seven months from the date of manufacture.
- Sheet intended to complement folding modified bitumen sheets -15ºC, as a replacement for oxyasphalt sheets.
- There is no chemical incompatibility between the Danosa range of SBS elastomeric bitumen and APP plastomeric bitumen membranes.
- Not to be used in a single-layer waterproofing system.
- Not suitable as cap sheet on green roofs; use GARDEN variant.
- Possible incompatibility between thermal insulation and waterproofing shall be checked.
- A separating layer (DANOFELT or DANODREN) shall be laid before laying the heavy protection (paving, gravel, topsoil, etc).
- Polyurethane foam shall not be sprayed directly on top of the waterproofing without the use of a suitable separating layer (geotextiles, mortar layers, polyethylene film, etc).
- If expansion that could affect the sheet is expected, a geotextile separating layer (Danofelt PY 200) shall be used between the sheet and the extruded polystyrene insulation panels, so that each product expands independently.
- NOTE: For more information on the Danosa systems in which this product is used, please see the document "Waterproofing Solutions".
Maintenance Recommendations
- Please refer to DANOSA UK Technical Statement ‘Flat Roof Waterproofing – Cleaning and Maintenance Recommendations’
Presentation
- Length (cm): 1200
- Width (cm): 100
- Thickness (mm): 2.5
- Surface (m²): 12
- Product code: 131071

Technical Data
Concept | Value | Standard |
---|---|---|
Mass per unit area (nominal) (kg/m²) | 3 | - |
Density (kg/m³) | 1200 | - |
External fire behaviour | PND | UNE-EN 1187; UNE-EN 13501-5 |
Durability flexibility | 0 ± 5 | - |
Creep durability (ºC) | 120 ±10 | UN-EN 1110 |
Elongation at break longitudinal (%) | PND | UNE-EN 12311-1 |
Elongation at transverse break (%) | PND | UNE-EN 12311-1 |
Watertightness at 10 kPa (Type A) | Pasa | UNE-EN 1928 |
Water vapour resistance factor (μ) | >100.000 | UNE-EN 1931 |
Low temperature flexibility (ºC) | <-10 | UNE-EN 1109 |
Reaction to fire | E | UNE-EN 11925-2; UNE-EN 13501-1 |
Resistance to static loading (kg) | PND | UNE-EN 12730 |
Resistance to root penetration | No Pasa | UNE-EN 13948 |
Longitudinal tensile strength (N / 5cm) | 350 ± 100 | UNE-EN 12311-1 |
Transverse tensile strength (N / 5cm) | 250 ± 100 | UNE-EN 12311-1 |
Longitudinal resistance to tearing (nail shank) (N) | PND | UNE-EN 12310-1 |
Transversal resistance to tearing (nail shank) (N) | PND | UNE-EN 12310-1 |
Resistance to impact, A (mm) | PND | UNE-EN 12691 |
Joint Strength: Welding Shear | PND | UNE-EN 12317-1 |
Hazardous substances | PND | - |
Addtitional Technical Data
Standards and Certification
- In accordance with the UNE-EN 13707 standard ‘Flexible sheets for waterproofing - Reinforced bitumen sheets for roof waterproofing - Definitions and characteristics’.
- In accordance with the UNE-EN 13969 standard for ‘Flexible sheets for waterproofing - Bitumen damp proof sheets including bitumen basement tanking sheets - Definitions and characteristics’.
- Complies with CE marking requirements.
Environmental Information
Concept | Value | Standard |
---|---|---|
Post-consumer recycled content (%) | 35 | - |
Manufactured in | Fontanar - Guadalajara (España) | - |