SONODAN PLUS AUTOADHESIVE
High-performance multi-layer board for airborne low frequency acoustic insulation
Product variations:


SONODAN PLUS Autoadhesive is a multilayer panel divided in two different layers. This differentiation allows the counterbalance during the installation, reducing the risk of lack of sealing:
First layer: formed by cross-linked polyethylene and a high density bituminous sheet finished in a self-adhesive film with non-stick plastic.
Second layer: formed by a high density bituminous sheet finished in self-adhesive film with non-stick plastic and an absorber panel of mineral wool.
Acoustically, the SONODAN PLUS Autoadhesive is based on the vibration of a membrane resonator (insulation at low frequencies) on elastic material (anti-impact).
Installation video

Advantages & Benefits
- Airborne sound insulation in music venues DnTA>70 dBA.
- By installing a second layer of plywood, watertight protection is ensured.
- As the membranes are self-adhesive, the second layer is easy to apply.
- High flexibility, allows for continuity of insulation in difficult encounters.
- Good reaction to low-frequency penetrative noises.
- Mineral wool attenuates medium and high frequencies.
- The membrane junction forms a resonator that attenuates low frequencies.
- Low thickness with high acoustic performance.
- Due to the dimensions of the panel, it is easier and faster to install on the ceiling.
- Due to its high level of tensile strength, it can be installed mechanically.
Instruction for Use
Preliminary operations:
Vertical and horizontal surfaces must be plastered with 1.5 cm of plaster. Before applying the product, it must be completely dry.
Note: DPS: Sound Insulation Installation Manual. Details of Singular Points.
Vertical and horizontal surfaces must be plastered with 1.5 cm of plaster. Before applying the product, it must be completely dry.
- If cementitious adhesive is used as a fixing method on both vertical and horizontal surfaces, plastering can be dispensed with.
- We could dispense with plastering as the cementitious adhesive layer acts as a regularising and sealing layer on the facing.
- If it is not possible to wait for the plaster to dry for reasons of speed of construction, we recommend using a direct plasterboard lining made of N15 board as a wall sealant.
- The first layer of SONODAN PLUS Self-Adhesive is installed against the substrate, so that the grey polyethylene presses against the wall, leaving the membrane visible. There are two methods of fixing the first layer:
- To begin with, choose a corner and lay the panel so that the largest dimension (1.2m) is at the top and fix it according to the chosen method.
- Half of the first layer of SONODAN PLUS Self-Adhesive is then placed on one wall and the other half on the adjoining wall, thus giving continuity to the membrane and facilitating the backing of the second layer.
- Continue laying panels of the first layer so that they are flush with the adjacent one.
- Remove the release film from the first layer of SONODAN PLUS Self-Adhesive once it has been fixed to the wall according to the chosen method.
- Lay the second layer so that the membranes meet and the rockwool is visible.
- To begin installing the second layer of SONODAN PLUS Self-Adhesive, start by removing the release film and placing the panel upside down against a corner so that the smallest dimension (1 m) is in height.
- Press the second layer against the first layer.
- The first layer of SONODAN PLUS Self-Adhesive is installed against the substrate so that the grey polyethylene is pressed against the slab and the membrane is visible. There are two methods of fixing the first layer:
- Mechanical fixing (as described on the wall).
- Adhesive fixing (as described on the wall).
- To begin with, a corner is selected by presenting the panel in such a way that the largest dimension (1.2 m) remains in width and it is fixed according to the chosen method.
- Half of the first layer of SONODAN PLUS Self-Adhesive is then placed on one wall and the other half on the ceiling, thus giving continuity to the membrane and facilitating the backing of the second layer.
- Continue laying panels of the first layer so that they are flush with the adjacent one.
- Remove the release film from the first layer of SONODAN PLUS Self-Adhesive once it has been fixed to the wall according to the chosen method.
- Lay the second layer of SONODAN PLUS Self-Adhesive so that the membranes meet and the rockwool is visible.
- To begin installing the second layer of SONODAN PLUS Self-Adhesive, start by removing the release film and placing the panel upside down against a corner, so that the smallest dimension (1 m) is in length.
- Then press the second layer against the first layer. For safety reasons, this second layer of SONODAN PLUS Self-Adhesive is fixed with Danosa Insulation Fixings, with a yield of 1 units per panel.
Note: DPS: Sound Insulation Installation Manual. Details of Singular Points.
Indications and Important Recommendations
- The facade cladding in a building must end at the dividing wall between different users. See SPD 2.1
- The roof can be additionally fastened to the ceiling by means of the damper hood.
- Drainage installations running through commercial premises must be insulated with ACUSTIDAN (see BAJ2 sheet) and protected with construction elements. Installation passages sealed with high density resilient materials. See SPD 1.2
- Partition walls must be plastered with at least 1 cm. See SPD 3.
- Never connect smoke vents to ventilation stacks.
- Do not perforate the floating roof with installations in commercial premises solution. Create technical sockets for electrical panels that are located in walls. See SDP 2.3 and SPD 4.4
- Partition walls should not be anchored to structural elements (except for roofs in dwellings) such as pillars and facades. In order to maintain the stability of the system, the tiling element must be bonded to the internal floating partition walls.
- It is not possible to perforate the floating roof with installations in the proposed solution in commercial premises. See SPD 4.4 and files TEF3 and TEF4
- Impact sound insulation must be used. See DANOSA Solutions Manual sheets SUF1 to SUF5.
- It should be taken into account that this product is part of a Sound Insulation system, so the Danosa Building Solutions Catalogue DIV4, TRA3, TEF3 and TEF4 sheets should be taken into account. Implementation of Sound Insulation. “Details of Singular Points” (SPD), as well as the rest of Danosa documentation.
- In the case of central heating or water intake installations, decoupling by means of a cross-linked polyethylene shell. See SPD 1.2
- If a battery-powered drilling machine is used (never with a mains power cable), the drill bit can be soaked in water to prevent the drill bit from becoming embedded in the asphalt.
Presentation
- Length (cm): 120
- Width (cm): 100
- Thickness (mm): 40
- Membrane thickness (mm): 2 + 2
- Polyethylene thickness (mm): 6
- Mineral wool thickness (mm): 30
- m² / package: 48
- Surface (m²): 1.2
- Product code: 610060

Technical Data
Concept | Value | Standard |
---|---|---|
Acoustic insulation in housing solution (dBA) | 63 | EN 717-1 |
Thermal conductivity of the insulation blanket 10 ºC (W/mK) | 0.041 | EN 12667 EN 12939 |
Thermal conductivity of the membrane 10 ºC (W/mK) | 0.130 | EN 12667 EN 12939 |
Thermal conductivity of cross-linked polyethylene (W / m K) | 0,038 | EN 12667 EN 12939 |
Rock wool thermal conductivity (W/m K) | 0.035 | EN 12667; EN 12939 |
Insulation blanket density (kg/m³) | 90 ± 10 | EN 845 |
Membrane density (kg/m³) | > 1600 | EN 845 |
Crosslinked Polyethylene Density (kg/m³) | > 25 | EN 845 |
Nominal mass of the membrane; the two layers (kg/m²) | 6 | EN 1849-1 |
Modulus of elasticity of cross-linked polyethylene (kPa) | > 1600 | - |
Reaction to fire | B s3 d0 | EN 13501-01 |
Longitudinal tensile strength (N / 5cm) | > 480 | EN 12311-1 |
Transverse tensile strength (N / 5cm) | > 275 | EN 12311-1 |
Resistance to tearing (nail shank) (N) | > 370 | EN 12310-1 |
Airflow resistance of the porous textile (KPa.s/m²) | 33 | EN 29053 |
Thermal resistance of the whole (m²K/W) | 1.05 | EN 12667; EN 12939 |
Work temperature (ºC) | -20 / +70 | - |
Thickness tolerance (%) | < 5 | EN 823 |
Tolerance Length and Width (%) | < 5 | EN 822 |
Addtitional Technical Data
Standards and Certification
- The sound certifications are the result of tests in an approved laboratory.
- *For any questions about information on the tests, please consult our Technical Department.
Laboratory | Test (EN 140-3) No | Result (EN 717-1) |
---|---|---|
L.G.A.I. | 102.669 | RA= 52.6 dBA |
L.G.A.I. | 94.004.366 | RA= 54.4 dBA |
LABEIN | B 130-134-H93 | RA= 62.6 dBA |
LABEIN | B 130-134-H94 | RA= 65.4 dBA |
The acoustic certifications are a consequence of several tests in homologated laboratories.
It complies with the Technical Building Code requirements for premises used in machinery rooms according to the DANOSA’s Sound Insulation Solutions Catalog, files AA-03; AA-24 y AA32.
It complies with the Technical Building Code requirements for premises used in machinery rooms according to the DANOSA’s Sound Insulation Solutions Catalog, files AA-03; AA-24 y AA32.
Environmental Information
Concept | Value | Standard |
---|---|---|
Manufactured in | Fontanar - Guadalajara (España) | - |