Roofing
- 1 Waterproofing support
- 2 Acoustic insulation and vapor barrier M.A.D.® PRO 100
- 3 Thermal and acoustic insulation of mineral wool
- 4 Acoustic insulation M.A.D.® PRO 50
- 5 Thermal and acoustic insulation of mineral wool
- 6 Separation layer DANECRAN® 100
- 7 Waterproofing membrane DANOPOL® HS 1.5 COOL ROOFING
- 8 Mechanical fastening of the waterproofing system
Perimeter
- 9 Adhesive DANOPOL® ADHESIVE
- 10 Finish strip DANOPOL® HS 1.5 COOL ROOFING
- 11 Clamped fastening profile DANOSA TIPO B
- 12 Elastic sealing ELASTYDAN® PU 40 GRIS
Advantages
Application
Graph
Technical Requirements
Function | Product | Description |
---|---|---|
Antiresonant acoustic insulation | M.A.D.® PRO 100 | High-density aluminized bituminous sheet. |
Antiresonant acoustic insulation | M.A.D.® PRO 50 | High-density aluminized bituminous sheet. |
Waterproofing | DANOPOL® HS 1.5 COOL ROOFING | High-durability PVC thermoplastic membrane mechanically fixed to the base support |
Unit of Work
Non-walkable flat roof (deck type) consisting of:
Vapor barrier and acoustic membrane finished with an aluminized film of 10 kg/m² and 5 mm thickness, M.A.D.® PRO 100; installed on top of the ribbing of the sheet; bare mineral wool panel with a total thickness of 100 mm and density of 150 kg/m³, fixed to the support using steel fixings (2 fixings per panel); acoustic membrane finished with an aluminized film of 5 kg/m², M.A.D.® PRO 50; bare mineral wool panel with a thickness of 100 mm and density of 150 kg/m³, fixed to the support using steel fixings (2 fixings per panel); waterproofing membrane made of PVC thermoplastic sheets with polyester mesh reinforcement, 1.5 mm thick, DANOPOL® HS 1.5 COOL ROOFING, mechanically fixed to the support. The fixings will have double threads, with corrosion treatment for 15 or 30 cycles according to external and internal moisture conditions, and will have their corresponding DITE or ETE.
Products with CE marking. Installation in accordance with UNE 104416. Measured surface area actually executed.
Vapor barrier and acoustic membrane finished with an aluminized film of 10 kg/m² and 5 mm thickness, M.A.D.® PRO 100; installed on top of the ribbing of the sheet; bare mineral wool panel with a total thickness of 100 mm and density of 150 kg/m³, fixed to the support using steel fixings (2 fixings per panel); acoustic membrane finished with an aluminized film of 5 kg/m², M.A.D.® PRO 50; bare mineral wool panel with a thickness of 100 mm and density of 150 kg/m³, fixed to the support using steel fixings (2 fixings per panel); waterproofing membrane made of PVC thermoplastic sheets with polyester mesh reinforcement, 1.5 mm thick, DANOPOL® HS 1.5 COOL ROOFING, mechanically fixed to the support. The fixings will have double threads, with corrosion treatment for 15 or 30 cycles according to external and internal moisture conditions, and will have their corresponding DITE or ETE.
Products with CE marking. Installation in accordance with UNE 104416. Measured surface area actually executed.