DANOPREN TL
Rigid extruded polystyrene (XPS) foam board for thermal insulation of pitched roofs.
Product variations:
BBA 19/5704 (1)
EPD-IES-0021369
DANOPREN TL is a rigid extruded polystyrene (XPS) foam board with a grooved surface finish on one side with shiplap edges. Comes at various thicknesses. Manufactured without CFC's, HCFC's or HFC's.
Instruction for Use
SLOPING ROOF
- The condition of the load-bearing substrate shall be checked to ensure that it is suitable for the various loads and overloads of the roof system.
- In case of a safety waterproofing on the load-bearing substrate, e.g. with double-sided self-adhesive sheets, the installation instructions for these products shall be followed. Maximum slopes in this case: 30 degrees (= 57%).
- The DANOPREN TL XPS insulation boards are installed on the substrate with the grooves parallel to the ridge in order to give the best possible anchorage to the mortar used to bond the tiles. The tiles are thus installed on the DANOPREN TL sheets in the traditional way, by a mortar bead, without the need to install an entire compression layer between the insulating sheets and the tiles.
- DANOPREN TL boards shall be mechanically fixed or bonded with a suitable adhesive to the substrate. Minimum fixing pattern: 4 fixings per board on the perimeter of the skirt and joints (e.g. chimneys); 2 fixings per board on the rest of the skirt. If adhesives are used, a similar distribution shall be maintained. Maximum slopes in this case: 45 degrees (= 100%). In any case, for each type of tile (curved, mixed, flat) the appropriate slope range shall be respected, according to the usual construction practice.
- A cavity shall be formed to cover the insulating sheets at gable ends and, above all, at the eaves, in order to retain them in case of possible movement or slippage.
- If the topographical situation is very exposed to wind, a special study is recommended to determine the best fixing system. In this case, however, the tile is always installed with mechanical fasteners (hooks, nails, etc.) and it is then necessary to interpose a screed, either fixed to the structural support by means of the DANOPREN TL sheets, or received with mortar to the sheets themselves.
Notice
- The information contained in this document and any other advice provided, are given in good faith, based on DANOSA's current knowledge and experience when products are properly stored, handled and applied, in normal situations and in accordance with the recommendations of DANOSA. The information applies only to the application (s) and the product (s) to which reference is expressly made. In case of changes in the parameters of the application, or in case of a different application, consult the DANOSA Technical Service before using the DANOSA products. The information contained herein does not exonerate the responsibility of the building agents to test the products for the application and intended use, as well as their correct application in accordance with current legal regulations. The product images used in our communications are indicative and may differ slightly in color and aesthetic appearance in relation to the final product.Orders are accepted in accordance with the terms of our current General Sales Conditions.DANOSA reserves the right to modify, without prior notice, the data reflected in this documentation.Website: www.danosa.com E-mail: info@danosa.com Telephone: +34 949 88 82 10
Presentation
- Length (cm): 125
- Width (cm): 60
- Thickness (mm): 50
- m² / package: 6
- Surface (m²): 0.75
- Colour: Blue
- Product code: 483004
Technical Data
| Concept | Value | Standard |
|---|---|---|
| water absorption by total immersion (Vol.%) | ≤ 0,7 | EN 12087 |
| Specific heat (J/kg·K) | 1450 | - |
| Capillarity | NULA | - |
| Coefficient of linear thermal expansion (mm/m·K) | 0,07 | - |
| Thermal conductivity declared (W/mK) | 0.033 | EN 12667 |
| Compression strength (kPa) | CS(10/Y)300 | EN 826 |
| Dimensional Stability (%) | ≤ 5 | EN 1604 |
| Water vapour diffusion resistance factor | ≥ 80 | EN 12086EN 12086 |
| Flatness (mm/m) | 6 | EN 825 |
| Reaction to fire | E | EN 13501-01 |
| Squareness (mm/m) | 5 | EN 824 |
| Compressive creep max 2% deflection after 50 years (kPa) | 95 | EN 1606 |
| Traction resistance perpendicular of the faces (kPa) | NPD | - |
| Water absorption by freeze-thaw cycling (Vol. %) | ≤ 1 | EN 12091 |
| Thermal Resistance (m²K/W) | 1,50 | EN 13164 |
| Min. service temperatures (ºC) | -50 | - |
| Máx. service temperatures (ºC) | 75 | - |
| Width Tolerance (± mm) | 8 | EN 822 |
| Thickness tolerance (mm) | -2/3 | EN 823 |
| Length tolerance (± mm) | 8 | EN 822 |
Addtitional Technical Data
| Concept | Value | Standard |
|---|---|---|
| water absorption by diffusion (Vol.%) | ≤ 3 | EN 12088 |
| Edge treatment | Media madera | - |
| Surface | Lisa; ranurada cara bajo teja | - |
Standards and Certification
- CTE DB-HE: Technical Building Code. Basic Document: Habitability. Energy saving
- In accordance with the UNE-EN 13164 standard for thermal insulation products for building applications. Manufactured extruded polystyrene (XPS) products.
- Complies with CE marking requirements.
- Directive 2010/31/EU. Energetic efficiency of the buildings
- Royal Decree 235/2013. Building energy certification
- BUREAU VERITAS company registration according to EN ISO 9001 granted to DANOSA's extruded polystyrene (XPS) manufacturing plant in Fontanar (Guadalajara).
- BUREAU VERITAS company registration according to EN ISO 9001 granted to DANOSA's extruded polystyrene (XPS) manufacturing plant in Leiria (Portugal).
- EU Regulation 305/2011. Construction products.