POLYDAN PRO 50/GP GREEN GARDEN.
First-rate SBS elastomeric 5 kg/m² capping sheet. Root Inhibitor.
Product variations:


High quality bituminous SBS modified capsheet reinforced with a heavy non-woven polyester felt. Includes root-resistant additive for living roof specifications.
The upper surface is finished with grey-green mineral chippings.
The underside has a quick-melt thermofusible film.
Designed for torch-applied applications and Safe2Torch details using hot-air.
Scope
- Tanking membrane.
- Capsheet in multi-layer waterproofing systems.
- Top sheet in two-layer membranes for waterproofing of roofs with heavy bonded, unbonded or floating protection.
- Single-layer membrane for waterproofing intensive and extensive green roofs.
- Single-layer membrane for waterproofing roofs with heavy bonded, unbonded or floating protection.
Advantages & Benefits
- High resistance to static and dynamic piercing.
- The mineral finish gives the membrane UV resistance.
- High resistance to root penetration.
- High tensile strength and high elongation at break.
- High resistance to tearing.
- Total impermeability to water and water vapour.
- Rot-proof.
- Very stable in the long term.
- Allows for adaptation to any type of geometry.
Support
- Old bitumen membranes.
- Concrete subsrates.
- Mortar subsrates.
Instruction for Use
Where falls apply, membrane rolls should be rolled up the slope so that water drains over and not into membrane overlaps.
Indications and Important Recommendations
- In case of new construction and renovation, possible chemical incompatibilities with APP plastomer-modified bitumen sheets shall be taken into account.
- In case of refurbishment, chemical incompatibilities with old waterproofing systems consisting of PVC membranes, modified tar-based mastics or any other, shall be taken into account, and it may be necessary to remove them completely or to use suitable separating layers.
- If it is necessary to adhere to metallic or slightly porous elements, a bituminous primer (IMPRIDAN 100) shall be applied to the entire surface to be welded beforehand.
- In the case of large trees and/or large root tissue, the membrane shall be protected (horizontal section and junctions with vertical walls) with a layer of reinforced concrete.
- This product may form part of a waterproofing system, so all the documents referred to in the Danosa Solutions Manual must be taken into account, as well as all the regulations and legislation that must be complied with in this respect.
- Self-protected sheets in coloured mineral or ceramic granules may have different colour shades depending on the different production batches. The mineral granule may darken naturally over time.
- There is no chemical incompatibility between the Danosa range of SBS elastomeric bitumen and APP plastomeric bitumen membranes.
- The planting of palms, palm trees, cypresses and bamboos is not recommended.
- For any questions about prohibited and/or non-recommended plants, please consult our Technical Department.
- Possible incompatibility between thermal insulation and waterproofing shall be checked.
- A separating layer (DANOFELT or DANODREN) shall be laid before laying the heavy protection (paving, gravel, topsoil, etc).
- Special attention must be paid to the execution of the singular points, such as parapets (meetings with vertical and emergent elements), drains, expansion joints, etc.
- Polyurethane foam shall not be sprayed directly on top of the waterproofing without the use of a suitable separating layer (geotextiles, mortar layers, polyethylene film, etc).
- If expansion that could affect the sheet is expected, a geotextile separating layer (Danofelt PY 200) shall be used between the sheet and the extruded polystyrene insulation panels, so that each product expands independently.
- NOTE: For more information on the Danosa systems in which this product is used, please see the document "Waterproofing Solutions".
Maintenance Recommendations
- Please refer to DANOSA UK Technical Statement ‘Flat Roof Waterproofing – Cleaning and Maintenance Recommendations’
Warning
- Do not apply on wet or frozen surfaces.
Handling, storage and preservation
- Before moving the pallet, check the condition of the shrink-wrap and reinforce if necessary.
- The product must be stored in a dry place protected from rain, sun, heat and low temperatures.
- The product must be stored in an upright position.
- Handle with a crane with a protective net.
- Pallets shall not be stacked on top of each other.
Notice
- The information contained in this document and any other advice provided, are given in good faith, based on DANOSA's current knowledge and experience when products are properly stored, handled and applied, in normal situations and in accordance with the recommendations of DANOSA. The information applies only to the application (s) and the product (s) to which reference is expressly made. In case of changes in the parameters of the application, or in case of a different application, consult the DANOSA Technical Service before using the DANOSA products. The information contained herein does not exonerate the responsibility of the building agents to test the products for the application and intended use, as well as their correct application in accordance with current legal regulations. The product images used in our communications are indicative and may differ slightly in color and aesthetic appearance in relation to the final product.Orders are accepted in accordance with the terms of our current General Sales Conditions.DANOSA reserves the right to modify, without prior notice, the data reflected in this documentation.Website: www.danosa.com E-mail: info@danosa.com Telephone: +34 949 88 82 10
Presentation
- Length (cm): 800
- Width (cm): 100
- Thickness (mm): 3.5
- Product code: 141102

Technical Data
Concept | Value | Standard |
---|---|---|
Mass per unit area (nominal) (kg/m²) | 5 | - |
External fire behaviour | Broof(t1) | UNE-EN 1187; UNE-EN 13501-5 |
Durability flexibility | -5 ± 5 | - |
Creep durability (ºC) | 100 ±10 | UN-EN 1110 |
Elongation at break longitudinal (%) | 45 ±15 | UNE-EN 12311-1 |
Elongation at transverse break (%) | 45 ±15 | UNE-EN 12311-1 |
Watertightness at 10 kPa (Type A) | Pasa | UNE-EN 1928 |
Water vapour resistance factor (μ) | 20.000 | UNE-EN 1931 |
Low temperature flexibility (ºC) | <-25 | UNE-EN 1109 |
Reaction to fire | E | UNE-EN 11925-2; UNE-EN 13501-1 |
Resistance to static loading (kg) | >20 | UNE-EN 12730 |
Resistance to root penetration | Pasa | UNE-EN 13948 |
Longitudinal tensile strength (N / 5cm) | 900 ± 250 | UNE-EN 12311-1 |
Transverse tensile strength (N / 5cm) | 650 ± 250 | UNE-EN 12311-1 |
Longitudinal resistance to tearing (nail shank) (N) | PND | UNE-EN 12310-1 |
Transversal resistance to tearing (nail shank) (N) | PND | UNE-EN 12310-1 |
Resistance to impact, A (mm) | >1000 | UNE-EN 12691 |
Resistance to impact, B (mm) | >1500 | - |
Joint Strength: Welding Shear | 650 ± 250 | UNE-EN 12317-1 |
Hazardous substances | NPD | - |
Addtitional Technical Data
Environmental Information
Concept | Value | Standard |
---|---|---|
Volatile organic compounds (COV's) (µg/m³) | 50 (A+) | ISO 16000-6:2006 |
Post-consumer recycled content (%) | 35 | - |
Manufactured in | Fontanar - Guadalajara (España) | - |